Electric dryer not heating or not drying? What to check first

This guide is for electric dryers. The checks come from GE's, Whirlpool's, Samsung's and LG's support pages and the US Consumer Product Safety Commission (CPSC), easiest and safest first. If you have a gas dryer and smell gas, leave the house and call your gas utility; for any gas-line work, call a licensed pro.

Safety first. The CPSC says fires can occur when lint builds up in the dryer or in the exhaust duct, because lint can block airflow and cause excessive heat build-up. GE says to unplug the dryer before any maintenance or cleaning, to reduce the chance of electric shock.

What to check, easiest first

  1. Check the cycle and settings. Whirlpool says an Air Only or Air/Fluff cycle adds no heat. GE says to choose Dry or More Dry rather than Eco Dry. Samsung and GE say Eco Dry deliberately reduces heat, and LG says Energy Saver, on by default for its Normal cycle, can leave clothes damp (LG).
  2. Clean the lint filter. GE says to remove and clean it each time you use the dryer, and that washing it in warm soapy water removes fabric-softener residue. The CPSC says to clean it before or after every load.
  3. Don't overload it. GE says to dry one wash load at a time and not to mix heavy and light items. Samsung says very wet loads and large items such as comforters take longer. GE adds that if clothes wring out easily after washing, the washer may need service.
  4. Check the breakers. A 240-volt dryer uses two breakers. Whirlpool says one runs the motor and one the heat, so a tripped breaker can leave a dryer that turns but does not heat. GE says to check the household fuse or circuit breaker, and that a 120-volt circuit makes drying take about three times longer. Samsung says to switch the breaker off for 30 seconds, then on.
  5. Test for heat. Whirlpool: run a heated timed cycle empty for 5 minutes, open the door and feel inside. If it heats but dries slowly, Whirlpool points to restricted airflow.
  6. Check the outside vent while the dryer runs. The CPSC says to check that exhaust air is escaping outside; if not, the vent or duct may be blocked. It also says damp clothes after a normal cycle can be a sign of a blocked lint screen or duct. GE says to check that the wall cap or damper opens easily.
  7. Clean and inspect the vent duct. GE says to clean the ductwork completely at least once a year, and to use solid metal 4-inch pipe rather than flexible white plastic, which can collapse and restrict airflow. Samsung says plastic or foil duct is not acceptable. The CPSC says to replace plastic or foil accordion duct with rigid or corrugated semi-rigid metal duct. If you disconnect the duct to clear a blockage, reconnect it before using the dryer.
  8. Cord and terminal connections: have a pro do this. Whirlpool lists making sure the cord is installed properly and the terminal screws are tight, with the dryer unplugged. This is electrical work, so have an electrician or a qualified technician do it.

Manufacturer and agency pages: Whirlpool, GE, Samsung and the CPSC dryer fire safety publication.

When to call a pro. If the checks above do not fix it, GE says there could be a service issue, and Whirlpool says to schedule service. Samsung says to call if there is no heat at all but its vent blockage test passes, or an error code shows. The CPSC says to have a qualified service person clean the inside of the dryer periodically. For anything beyond a breaker, cord check or vent cleaning, such as heating parts, call a pro.

The exact steps differ by brand and model, so follow your owner's manual. Not sure of your model? See how to find your model number and how to find the manual.

GE, Whirlpool, Samsung and LG are trademarks of their respective owners. HomeGear isn't affiliated with or endorsed by them or by the CPSC.

Looking for your dryer's label? See dryer model number and lifespan.

Common questions

  • Why does my dryer run but not heat? Often a setting (Air or Eco cycle), a tripped half of the two-breaker circuit, or a blocked vent. Work through the steps above.
  • Why do my clothes take two cycles to dry? The CPSC lists longer-than-normal drying as a possible sign of a blocked lint screen or exhaust duct. Check both.
  • How often should I clean the vent duct? GE says at least once a year.
Download on the App StoreGet it on Google Play